					Possible Cause 
			 | 
			
				    | 
			
				 
					Possible Remedy 
			 | 
		
		
			| 
				 
					Failed diaphragm 
			 | 
			
				 
					  
			 | 
			
				 
					Replace using correct actuator service kit 
			 | 
		
		
			| 
				 
					Seized valve 
			 | 
			
				 
					  
			 | 
			
				 
					Free valve/replace complete turbine housing sub-assembly 
			 | 
		
		
			| 
				 
					Leaking hose 
			 | 
			
				  | 
			
				 
					Replace hose and clips 
			 | 
		
		
			| 
				 
					Wastegate mechanism set incorrectly 
			 | 
			
				 
					  
			 | 
			
				 
					Contact United Fuel Injection for correct setting details 
			 | 
		
		
			| 
				 
					Dirty air cleaner 
			 | 
			
				 
					  
			 | 
			
				 
					Clean or replace element according to manufacturer's recommendations 
			 | 
		
		
			| 
				 
					Restricted compressor intake duct 
			 | 
			
				 
					  
			 | 
			
				 
					Remove restriction or replace damaged parts as required 
			 | 
		
		
			| 
				 
					Restricted air duct from compressor to intake manifold 
			 | 
			
				  | 
			
				 
					Remove restriction or replace damaged parts as required 
			 | 
		
		
			| 
				 
					Restricted intake manifold 
			 | 
			
				  | 
			
				 
					Refer to engine manufacturer's manual and remove restriction 
			 | 
		
		
			| 
				 
					Air leak in feed from compressor to intake manifold 
			 | 
			
				  | 
			
				 
					Replace seals, gaskets or tighten fastners as required 
			 | 
		
		
			| 
				 
					Air leak beween intake manifold and engine 
			 | 
			
				  | 
			
				 
					Refer to engine manufacturer's manual and replace gaskets or tighten fastners 
			 | 
		
		
			| 
				 
					Restricted exhaust system 
			 | 
			
				  | 
			
				 
					Remove restriction or replace damaged parts as required 
			 |